5930-01-076-9650 ADAPTER,SWITCH ACTUATOR Index 5961-01-076-9655 SEMICONDUCTOR DEVICE SET

National Stock Number:
6130-01-076-9654

Federal Supply Class:
6130

National Item Identification Number:
010769654

Description:
POWER SUPPLY

Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
91473137F6481THALES SA
LOS-W-580103VEECO INSTRUMENTS INC LAMBDA DIV


Techincal Specification:
ELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
FEATURES PROVIDEDFILTER
INPUT FREQUENCY RATING47.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT
INPUT FREQUENCY RATING47.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT
INPUT CONNECTION QUANTITY4 1ST OPERATING POWER RQMT
INPUT CONNECTION QUANTITY4 2ND OPERATING POWER RQMT
INPUT CONNECTION TYPETERMINAL STRIP 1ST OPERATING POWER RQMT
INPUT CONNECTION TYPETERMINAL STRIP 2ND OPERATING POWER RQMT
INPUT VOLTAGE RATING210.0 AC VOLTS MINIMUM AND 250.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT
INPUT PHASESINGLE 2ND OPERATING POWER RQMT
INPUT PHASESINGLE 1ST OPERATING POWER RQMT
INPUT VOLTAGE RATING105.0 AC VOLTS MINIMUM AND 125.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT
LOAD TYPERESISTIVE SINGLE POWER OUTPUT
OUTPUT CONNECTION QUANTITY2 SINGLE POWER OUTPUT
OUTPUT CONNECTION TYPETERMINAL STRIP SINGLE POWER OUTPUT
OUTPUT CONTROL LOCATIONFRONT PANEL SINGLE POWER OUTPUT
OUTPUT CONTROL QUANTITY1 SINGLE POWER OUTPUT
OUTPUT CONTROL TYPEVOLTAGE ADJUSTMENT SINGLE POWER OUTPUT
OUTPUT CURRENT RATING8.5 DC AMPERES MINIMUM AND 12.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT
OUTPUT VOLTAGE RATING4.8 DC VOLTS MINIMUM AND 5.2 DC VOLTS MAXIMUM SINGLE POWER OUTPUT
OVERALL HEIGHT2.750 INCHES NOMINAL
OVERALL LENGTH9.000 INCHES NOMINAL
OVERALL WIDTH4.875 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE+0.1 TO 60.0 CELSIUS
RECTIFICATION METHODSINGLE PHASE FULL WAVE CENTER TAP