National Stock Number: 6680-01-027-6176
Federal Supply Class: 6680
National Item Identification Number: 010276176
Description: METER,FLUID FLOW INDICATING,DIFF
Detail: An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
|
Manufacturer Information:
06EBXXX0X60A1BXXXX01 | 05991 | CAMERON ENERGY SERVICES CORP. | D4-224E005 | 05991 | CAMERON ENERGY SERVICES CORP. |
|
Techincal Specification:
DEPTH | 4.656 INCHES NOMINAL | DIAMETER | 3.141 INCHES NOMINAL | ACCESSORY COMPONENTS AND QUANTITY | 2.000 IN. BERYLLIUM COPPER SNESOR W/STEEL HOUSING,1 | CASE MATERIAL | ALUMINUM, CAST | CASE SHAPE | ROUND | CRITICALITY CODE JUSTIFICATION | CPYY AND ASPF AND FEAT | MAXIMUM DIFFERENTIAL PRESSURE | 60.0 ON. OF WATER COLUMN | III MEDIA FOR WHICH DESIGNED | LIQUID | INLET CONNECTION SIZE | 1/4 IN. 18 THD NPT | PRESSURE TYPE | LOW OR HIGH | PROPRIETARY CHARACTERISTICS | PACS | MOUNTING TYPE | FLUSH | OUTLET CONNECTION SIZE | 1/4 IN. 18 THD NPT | SCALE INSCRIPTION/BACKGROUND COLOR | BLACK MARKINGS ON WHITE BACKGROUND | SCALE PRESENTATION RANGE | 0 TO 60 RANGE OF NUMERICAL MARKINGS | SPECIAL FEATURES | 3.000 IN. DIA DIAL | TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
|
|