National Stock Number: 6665-00-161-8120
Federal Supply Class: 6665
National Item Identification Number: 001618120
Description: RADIACMETER
Detail: AN ITEM SPECIFICALLY DESIGNED TO DETECT AND MEASURE RADIOACTIVE ENERGY; INDICATES DIRECTLY. IT MAY OR MAY NOT INCLUDE THE FUNCTION OF A RADIAC COMPUTER.
|
Manufacturer Information:
450P | 63060 | HEICO OHMITE LLC DBA OHMITE MFG CO INC | 666 | 63060 | HEICO OHMITE LLC DBA OHMITE MFG CO INC |
|
Techincal Specification:
SPECIAL FEATURES | WEIGHT 0.85 KG; PORTABLE SURVEY METER CONSISTING OF A PRESSURIZED IONIZATION CHAMBER, MICROPROCESSOR-BASSED WITH COMBINED ILLUMINATED ANALOG/DIGITAL LCD; UTILIZES AN INFRARED COMMUNICATOR FOR CALIBRATION AND ALLOWS THE INSTRUMENT TO BE USED AS A REMOTE DETECTOR; INCLUDES PROGRAMMABLE FLASH ALARM WHICH CAUSES THE DISPLAY TO PULSATE AT A RATE OF ONCE PER SECOND WHEN MEASURED DOSE EXCEEDS A PRESET LIMIT; IONIZATION CHAMBER FILLED TO A PRESSURE OF 6 ATMOSPHERES; CAN BE USED TO FREEZE THE MAX. EXPOSURE RATE ENCOUNTERED; 5 OPERATING RANGES, 0 TO 500 MICRO R/H, 0 TO 5 MR/H, 0 TO 50 MR/H, 0 TO 500 MR/H AND 0 TO 5 R/HOUR | RADIATION TYPE AND FUNCTION | BETA RAYS DETECTS | | GAMMA RAYS DETECTS | | X-RAYS DETECTS | | BETA RAYS MEASURES | | GAMMA RAYS MEASURES | | X-RAYS MEASURES | RADIATION RANGE PER HOUR | 0.0 TO 5.0 ROENTGENS | ACCURACY IN PERCENT | 0.0 TO 10.0 AT FULL SCALE | INDICATOR TYPE | METER | DETECTING ELEMENT TYPE | IONIZATION CHAMBER | PORTABILITY | PORTABLE | CARRYING CASE | NOT PROVIDED | CASE MATERIAL | PLASTIC | OVERALL LENGTH | 8.000 INCHES NOMINAL | OVERALL WIDTH | 4.000 INCHES NOMINAL | OVERALL HEIGHT | 6.000 INCHES NOMINAL |
|
|