Description:
TEST SET,TELECOMMUNICATION SYSTE

Detail:
A TEST SET DESIGNED FOR USE IN EXAMINING A TELECOMMUNICATION SYSTEM OR SUBSYSTEM, AND PROVIDING DISCREET EVALUATION OF ITS PERFORMANCE. ITS TESTING CAPABILITIES ARE MULTIAPPLICATION AND NOT LIMITED TO MEASURING SINGLE PERFORMANCE CHARACTERISTICS. PROVIDES THE FACILITIES FOR VOICE-GRADE, PROGRAM AND/OR DATA LINE TESTING.


Manufacturer Information:
D-863933592MITEQ, INC


Techincal Specification:
ENCLOSURE FEATURESINGLE ITEM W/HOUSING
AC VOLTAGE RATING250.0 VOLTS MAXIMUM
FREQUENCY RATING47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM
FUNCTIONAL DESCRIPTIONCONVERSION LOSS 15 DB, 18 DB WITH OPTIONS 1 OR 2; AMPLITUDE RESPONSE PORM 0.25 DB OVER ANY 40 MHZ, PORM 1 DB OVER OUTPUT FREQUENCY BAND; INPUT/OUTPUT RETURN LOSS 20 DB MIN; LEVEL CONTROL 30 DB, 0.2 DB STEP SIZE; INTERMODULATION DISTORTION WITH TWO INBAND SIGNALS AT M13 DBM INPUT, THRID ORDER INTERMODULATION PRODUCTS ARE LESS THAN 50 DBC; INPUT/OUTPUT ISOLATION 60 DB MIN
HEIGHT3.500 INCHES NOMINAL
LENGTH20.000 INCHES MAXIMUM
SPECIAL FEATURESBAND 1 RF INPUT 5.85-6.425 GHZ, LO FREQUENCY 2.225 GHZ; RF OUTPUT 3.625-4.2 GHZ; BAND 2 RF INPUT 6.425-6.725 GHZ, LO FREQUENCY 3.025 GHZ, RF OUTPUT 3.4-3.7 GHZ; VOLTAGE 100, 120, 220, 230/240 VAC PORM 10 PCT, -13 PCT, REAR PANEL SELECTABLE, 250 VAC MAX; FREQUENCY 47-63 HZ; POWER CONSUMPTION 120 W TYPICAL; CONNECTORS RF N FEMALE, FRONT PANEL, REAR PANEL WITH OPTION 10; EXTERNAL REFERENCE INPUT, OPTION 6, BNC FEMALE, REAR PANEL; SUMMARY ALARM DE-9P, REAR PANEL; REMOTE INTERFACE, REAR PANEL, DE-9S FOR RS485 AND RS422, DB-25P FOR RS232, DB25S FOR CONTACT CLOSURE, IEEE-488 RECEPTACLE FOR GPIB, EXTERNAL LOCAL OSCILLATOR INPUT, OPTION 4 SMA FEMALE, REAR PANEL; TEST POINTS, FRONT PANEL DC VOLTAGE DISPLAY, LO PHASE VOLTAGE DISPLAY, LO FREQUENCY/POWER MONITOR SMA FEMALE
WIDTH19.000 INCHES NOMINAL
SUPPLEMENTARY FEATURESENVIRONMENTAL OPEATING AMBIENT TEMPERATURE 0-50 DEG C, RELATIVE HUMIDITY UP TO 95 PCT AT 30 DEG C, ATMOSPHERIC PRESSURE UP TO 10,000 FEET; NONOPERATING AMBIENT TEMP M50-70 DEG C, RELATIVE HUMIDITY UP TO 95 PCT AT 40 DEG C, ATMOSPHERIC PRESSURE UP TO 40,000 FEET, SHOCK AND VIBRATION NORMAL HANDLING BY COMMERCIAL CARRIERS
TEST TYPE FOR WHICH DESIGNEDFREQUENCY TRANSLATION FOR SATELLITE COMMUNICATIONS