ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.376 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.376 INCHES NOMINAL |
CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
FURNISHED ITEMS AND QUANTITY | MTG HARDWARE 2,TERM. HARDWARE |
INDICATOR TYPE | DIAL W/POINTER |
INSTALLATION DESIGN | PANEL |
NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
OVERALL HEIGHT | 4.250 INCHES MINIMUM AND 4.750 INCHES MAXIMUM |
OVERALL LENGTH | 10.000 INCHES MAXIMUM |
OVERALL WIDTH | 4.250 INCHES MINIMUM AND 4.750 INCHES MAXIMUM |
MEASUREMENT RANGE | +0.0 TO 150.0 VOLTS, AC SINGLE INDICATOR SINGLE RANGE |
METER DEPTH BEHIND MOUNTING FLANGE | 9.000 INCHES MAXIMUM |
METER BODY DIAMETER BEHIND MOUNTING FLANGE | 3.980 INCHES MAXIMUM |
MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
MOUNTING STUD LENGTH | 0.625 INCHES NOMINAL |
MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
MOVEMENT SUSPENSION METHOD | TAUT BAND |
POINTER COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
SCALE DIVISION QUANTITY | 30 SINGLE INDICATOR SINGLE RANGE |
SCALE GRADUATION TYPE | LINEAR SINGLE INDICATOR SINGLE RANGE |
SCALE SELECTION METHOD | TERMINAL |
SENSITIVITY RATING | 5.0 AMPERES |
SPECIFICATION/STANDARD DATA | 81349-MIL-M-16034/3 GOVERNMENT SPECIFICATION |
STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
TEST DATA DOCUMENT | 81349-MIL-16034 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |