CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
CIRCUIT ATTACHMENT METHOD AND QUANTITY | 3 BINDING POST |
INDICATOR TYPE | DIAL W/POINTER |
INSTALLATION DESIGN | BENCH OR HAND HELD |
MEASUREMENT RANGE | +0.0 TO 3.0 KILOHMS SINGLE INDICATOR 4TH RANGE |
MEASUREMENT RANGE | +0.0 TO 3.0 OHMS SINGLE INDICATOR 1ST RANGE |
MEASUREMENT RANGE | +0.0 TO 30.0 OHMS SINGLE INDICATOR 2ND RANGE |
MEASUREMENT RANGE | +0.0 TO 300.0 OHMS SINGLE INDICATOR 3RD RANGE |
POWER SOURCE | INTERNAL |
REFERENCE DATA AND LITERATURE | TO 33A1-12-310-1 |
SCALE SELECTION METHOD | SWITCH |
SUPPLEMENTARY FEATURES | VIBROGROUND FOR TESTING EARTH GROOUNDS; EXPLOSION PROOF VERSION |