6625-00-649-1632 AMMETER Index 6625-00-649-1635 AMMETER

National Stock Number:
6625-00-649-1633

Federal Supply Class:
6625

National Item Identification Number:
006491633

Description:
AMMETER

Detail:
An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see GALVANOMETER.


Manufacturer Information:
MIL-M-10304/581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-10304/581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MR26P050DCUAR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ACCURACY IN PERCENT-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
BACKGROUND COLORWHITE SINGLE INDICATOR SINGLE RANGE
CIRCUIT CONSTRUCTION TYPENONELECTRONIC
CIRCUIT CURRENT FOR WHICH DESIGNEDDC
CIRCUIT ATTACHMENT METHOD AND QUANTITY2 SOLDER STUD
DIAL SCALE MARKING COLORBLACK SINGLE INDICATOR SINGLE RANGE
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS3000.0
ENVIRONMENTAL PROTECTIONDUSTPROOF
FEATURES PROVIDEDMAGNETIC SHIELD AND ZERO ADJUSTER
FSC APPLICATION DATATEST SET ELECTRONIC
INDICATOR TYPEDIAL W/POINTER
INSTALLATION DESIGNPANEL
OVERALL DIAMETER2.695 INCHES NOMINAL
OVERALL LENGTH2.000 INCHES NOMINAL
PANEL FOR WHICH DESIGNEDMAGNETIC
MATERIALSTEEL
MEASUREMENT RANGE+0.0 TO 50.0 MICROAMPERES, DC SINGLE INDICATOR SINGLE RANGE
METER BODY DIAMETER BEHIND MOUNTING FLANGE2.210 INCHES NOMINAL
METER DEPTH BEHIND MOUNTING FLANGE1.600 INCHES NOMINAL
MOUNTING BOLT CIRCLE DIAMETER2.440 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLETHREE HOLE/STUD BOLT CIRCLE
MOUNTING FACILITY TYPE AND QUANTITY1 FLANGE
MOVEMENT SUSPENSION METHODMETAL PIVOT BASE
MOVEMENT TYPEMOVING COIL, PERMANENT MAGNET
NUCLEAR HARDNESS CRITICAL FEATURENONHARDENED
POINTER COLORBLACK SINGLE INDICATOR SINGLE RANGE
POWER SOURCEEXTERNAL
SCALE DIVISION QUANTITY6 SINGLE INDICATOR SINGLE RANGE
SCALE GRADUATION TYPELINEAR SINGLE INDICATOR SINGLE RANGE
SCALE SELECTION METHODSWITCH
SENSITIVITY RATING150.0 MILLIVOLTS
SPECIAL MARKINGSSEALED-DO NOT OPEN
SPECIAL FEATURESRUGGEDIZED
STYLE DESIGNATORROUND FLUSH MTG
SURFACE TREATMENTENAMEL SEMIGLOSS
TEST DATA DOCUMENT81349-MIL-M-10304 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).