6145-01-350-6941 CABLE,SPECIAL PURPOSE,ELECTRICAL Index 6145-01-350-6943 CABLE,SPECIAL PURPOSE,ELECTRICAL

National Stock Number:
6145-01-350-6942

Federal Supply Class:
6145

National Item Identification Number:
013506942

Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
1XTA2419362FKJ12515NEXANS AEROSPACE USA LLC
24444/E283GK-292607CARLISLE INTERCONNECT TECHNOLOGIES INC
24TETFN19362KXE12814CARLISLE INTERCONNECT TECHNOLOGIES, INC.
51-5022005973CHAMPLAIN CABLE CORP SUB OF HUBER AND SUHNER INC
LE572-0003-000643999THE BOEING COMPANY


Techincal Specification:
COLORWHITE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSWHITE 3RD POSITION JACKET CABLE
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY1 TWISTED PAIR
CONDUCTOR QUANTITY2
CROSS SECTION OUTSIDE DIAMETER0.108 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B355 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER ALLOY CORE CONDUCTOR ALL CONDUCTORSPLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSPLASTIC POLYIMIDE 2ND POSITION TAPE CABLEPLASTIC PERFLUOROALKOXY 3RD POSITION JACKET CABLE
SPECIAL FEATURESA BLUE COLOR BAND SHALL BE APPLIED EVERY 2 3/4 INCHES ON ONE BASIC WIRE FOR SIZE IDENTIFICATION
ROUND CONDUCTOR SIZE24 AWG ALL CONDUCTORS
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR36 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B355 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTNICKEL CORE CONDUCTOR ALL CONDUCTORS
TEMP RATING200.0 CELSIUS