6145-01-217-0889 CABLE,SPECIAL PURPOSE,ELECTRICAL Index 6145-01-217-0891 CABLE,SPECIAL PURPOSE,ELECTRICAL

National Stock Number:
6145-01-217-0890

Federal Supply Class:
6145

National Item Identification Number:
012170890

Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
2112054207ELECTROWEAVE INC
976283-13B150RAYTHEON COMPANY
976283-149956RAYTHEON COMPANY
T-05TP/05TP2419XBN99832SCOTT HUBER ESSICK A CO OF FIGGIE INTERNATIONAL INC


Techincal Specification:
COLOR CODING DOCUMENT976283-49956 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
COLORWHITE 1ST POSITION JACKET CABLE
CONDUCTOR ARRANGEMENT AND QUANTITY10 TWISTED PAIR
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY20
CROSS-SECTIONAL SHAPE STYLEFLAT
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
MATERIALPLASTIC POLYHEXAMETHYLENE ADIPAMIDE 1ST POSITION JACKET CABLE
MATERIALPLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
ROUND CONDUCTOR SIZE24 AWG ALL CONDUCTORS
SPECIAL FEATURESPRIMARY INSULATION IS IRRADIATED AND EACH TWISTED PAIR WOVEN TOGETHER WITH A 2 X 2 TWILL WEAVE AND OPTIONAL YARN COLOR NATURAL
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR36 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
TEMP RATING79.0 CELSIUS


Click here to Register for Free 30-day Trial