6145-01-205-3627 CABLE,POWER,ELECTRICAL Index 6145-01-205-3629 CABLE,POWER,ELECTRICAL

National Stock Number:
6145-01-205-3628

Federal Supply Class:
6145

National Item Identification Number:
012053628

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
LSDSGU-20081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M24643/15-09UN81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-24643/1581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-DTL-24643/1581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
COLORBLACK 1ST POSITION COVER FIRST CONDUCTOR
COLORBLACK 1ST POSITION JACKET CABLE
COLORWHITE 2ND POSITION COVER SECOND CONDUCTOR
CONDUCTOR ARRANGEMENT AND QUANTITY2 SINGLES
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY2
CROSS SECTION OUTSIDE DIAMETER1.573 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B3 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALGLASS FIBER AND FIBER SYNTHETIC 1ST POSITION TAPE ALL CONDUCTORS
MATERIALPLASTIC CROSS-LINKED POLYOLEFIN 1ST POSITION JACKET CABLE
ROUND CONDUCTOR SIZE0000 AWG ALL CONDUCTORS
VOLTAGE RATING1000.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR15 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR61 ALL CONDUCTORS