6145-01-160-4623 CABLE,POWER,ELECTRICAL Index 6145-01-160-4626 CABLE,SPECIAL PURPOSE,ELECTRICAL

National Stock Number:
6145-01-160-4624

Federal Supply Class:
6145

National Item Identification Number:
011604624

Description:
WIRE,ELECTRICAL

Detail:
A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. refers to buld quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see WIRE,(as modified), Includes Litz wire and insulated/uninsulated armored, and ground wire. Excludes BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE and MAGNET WIRE.


Manufacturer Information:
7033483P503538LOCKHEED MARTIN CORPORATION
M16878/17BGA981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-W-16878/1781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
COLORWHITE 1ST POSITION COVER SINGLE CONDUCTOR
CONDUCTOR FORMSOLID SINGLE CONDUCTOR
CROSS SECTION OUTSIDE DIAMETER0.070 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
DEPARTURE FROM CITED DOCUMENTAS MODIFIED BY O/A DIAMETER
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALPLASTIC POLYAMIDE 2ND POSITION JACKET SINGLE CONDUCTOR
MATERIALPLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
ROUND CONDUCTOR SIZE20 AWG SINGLE CONDUCTOR
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
SURFACE TREATMENTTIN CORE CONDUCTOR SINGLE CONDUCTOR
TEMP RATING-54.0 CELSIUS AND 105.0 CELSIUS


Click here to Register for Free 30-day Trial