6210-01-059-7598 LENS,LIGHT Index 6145-01-059-7603 CABLE,POWER,ELECTRICAL

National Stock Number:
6145-01-059-7599

Federal Supply Class:
6145

National Item Identification Number:
010597599

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
M27500B12TA4U001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
M27500B12TA4U0081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-2750081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
NEMA-WC275001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
ST5M1298-12T4U076301THE BOEING COMPANY


Techincal Specification:
COLORYELLOW 1ST POSITION COVER ALL CONDUCTORS
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY4
CONDUCTOR ARRANGEMENT AND QUANTITY1 TWISTED TOGETHER W/NO OUTER COVERING
CROSS-SECTIONAL SHAPE STYLETWIST
CROSS-SECTIONAL HEIGHT0.268 INCHES NOMINAL
CROSS-SECTIONAL WIDTH0.268 INCHES NOMINAL
DEPARTURE FROM CITED DOCUMENTAS MODIFIED BY BASIC BODY COLOR PER CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B355 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE12 AWG ALL CONDUCTORS
SPECIAL FEATURESOPTIONAL IDENTIFICATION METHOD TWO APPLIES
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR25 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B355 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTNICKEL CORE CONDUCTOR ALL CONDUCTORS
TEMP RATING260.0 CELSIUS


Click here to Register for Free 30-day Trial