National Stock Number: 6145-01-042-9008
Federal Supply Class: 6145
National Item Identification Number: 010429008
Description: CABLE,POWER,ELECTRICAL
Detail: Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.
|
Manufacturer Information:
000-8006-291 | 94756 | THE BOEING COMPANY | 02717 | 81774 | GENERAL CABLE CORPORATION | 19106 | 16428 | BELDEN WIRE & CABLE COMPANY LLC DBA BELDEN CDT ELECTRONICS DIVISION | 19106 | 2W733 | BELDEN WIRE AND CABLE CO WIRE AND CABLE OFFICE | 19206 | 2W733 | BELDEN WIRE AND CABLE CO WIRE AND CABLE OFFICE | J-C-580 | 81348 | FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC | J-C-580S6CK3/12RRJ | 81348 | FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC | SI-53161-117 | 24457 | GENERAL ELECTRIC CO WIRE AND CABLE BUSINESS DEPT | W-4232-78-07-BLACK | 07909 | SOUTHWIRE COMPANY DOUGLAS PLANT | W-4232-78-07-BLACK | 82879 | YORK TECHNICAL INSTITUTE LLC |
|
Techincal Specification:
COLOR | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR | COLOR | BLACK 2ND POSITION JACKET CABLE | COLOR | GREEN 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR | COLOR | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR | CONDUCTOR ARRANGEMENT AND QUANTITY | 3 SINGLES | CONDUCTOR FORM | STRANDED ALL CONDUCTORS | CONDUCTOR QUANTITY | 3 | CROSS SECTION OUTSIDE DIAMETER | 0.640 INCHES NOMINAL | CROSS-SECTIONAL SHAPE STYLE | ROUND | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS | MATERIAL | RUBBER 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS | MATERIAL | RUBBER 2ND POSITION JACKET CABLE | ROUND CONDUCTOR SIZE | 12 AWG ALL CONDUCTORS | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS | STRAND QUANTITY PER CONDUCTOR | 65 ALL CONDUCTORS | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS | TEMP RATING | 60.0 CELSIUS |
|
|