National Stock Number: 6145-01-026-9085
Federal Supply Class: 6145
National Item Identification Number: 010269085
Description: CABLE,POWER,ELECTRICAL
Detail: Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.
|
Manufacturer Information:
M27500-16ML7T08 | 1P787 | NATIONAL ELECTRICAL MFRS ASSN DBA NEMA | M2750016ML7T08 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | MIL-C-27500 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | NEMA-WC27500 | 1P787 | NATIONAL ELECTRICAL MFRS ASSN DBA NEMA |
|
Techincal Specification:
CONDUCTOR ARRANGEMENT AND QUANTITY | 7 SINGLES | CONDUCTOR FORM | STRANDED ALL CONDUCTORS | CONDUCTOR QUANTITY | 7 | CROSS-SECTIONAL SHAPE STYLE | ROUND | MATERIAL | COPPER 1ST POSITION SHIELD BRAID, METALLIC CABLE | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS | MATERIAL | PLASTIC POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET CABLE | MATERIAL | PLASTIC POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET ALL CONDUCTORS | MATERIAL | PLASTIC POLYALKENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS | ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS | STRAND AWG SIZE PER CONDUCTOR | 29 ALL CONDUCTORS | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS | SURFACE TREATMENT | TIN ALLOY 1ST POSITION COATING CABLE | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS | TEMP RATING | 150.0 CELSIUS | TEST DATA DOCUMENT | 27500-ZA81349-MIL-C- SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
|
|