4730-01-528-4129 NOZZLE,SPRAY,FLUID-EMULSION Index 7125-01-528-4131 CLIP,SHELF SUPPORT

National Stock Number:
6130-01-528-4130

Federal Supply Class:
6130

National Item Identification Number:
015284130

Description:
POWER SUPPLY

Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
J24V/1A0E5V2WESTCOR CORP SUB OF VICOR CORP


Techincal Specification:
INPUT VOLTAGE RATING115.0 AC VOLTS MINIMUM AND 230.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
INPUT FREQUENCY RATING47.0 HERTZ MINIMUM AND 500.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
INPUT PHASESINGLE SINGLE OPERATING POWER RQMT
OPERATING AMBIENT TEMP RANGE+0.0 TO 45.0 CELSIUS
OUTPUT CONTROL LOCATIONFRONT PANEL SINGLE POWER OUTPUT
OUTPUT CURRENT RATING1.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT
OUTPUT WATTAGE RATING1200.0 WATTS MINIMUM AND 1600.0 WATTS MAXIMUM SINGLE POWER OUTPUT
OUTPUT VOLTAGE RATING24.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT
RIPPLE VOLTAGE AT FULL LOAD100.0 MILLIVOLTS PEAK SINGLE POWER OUTPUT
SPECIAL FEATURESSTORAGE TEMP M40.0 TO P85.0 DEG C; HUMIDITY 0-95 PCT NONCONDENSING; ALTITUDE 2.6 PCT TOTAL OUTPUT POWER FOR EACH 1,000 FT TO A MAX OPERATING ALTITUDE OF 15,000 FT. NON OPERATING STORAGE MAX ALTITUDE IS 40K