6130-01-267-2401 POWER SUPPLY Index 6130-01-267-2403 POWER SUPPLY

National Stock Number:
6130-01-267-2402

Federal Supply Class:
6130

National Item Identification Number:
012672402

Description:
POWER SUPPLY

Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
801659-50153938EVANS & SUTHERLAND COMPUTER CORP
Z15BX1-858910ABBOTT TECHNOLOGIES, INC


Techincal Specification:
ELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
FEATURES PROVIDEDREMOTE ERROR SENSING CAPABILITY AND OVER VOLTAGE PROTECTOR AND FUSE
INPUT FREQUENCY RATING47.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
INPUT VOLTAGE RATING180.0 AC VOLTS MINIMUM AND 265.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING90.0 AC VOLTS MINIMUM AND 132.0 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
INPUT PHASESINGLE SINGLE OPERATING POWER RQMT
OUTPUT CURRENT RATING8.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT
OUTPUT VOLTAGE RATING14.2 DC VOLTS MINIMUM AND 15.7 DC VOLTS MAXIMUM SINGLE POWER OUTPUT
OVERALL HEIGHT2.250 INCHES NOMINAL
OVERALL LENGTH6.750 INCHES NOMINAL
OVERALL WIDTH4.000 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE-0.1 TO 85.0 CELSIUS
POWER SUPPLY EFFICIENCY LINE75.0
VENTILATION DESIGN TYPEAMBIENT AIR