ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
FEATURES PROVIDED | REMOTE ERROR SENSING CAPABILITY AND VOLTAGE ADJUSTMENT AND OVER VOLTAGE PROTECTOR |
INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |
INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
INPUT VOLTAGE RATING | 103.5 AC VOLTS MINIMUM AND 126.5 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
OUTPUT CONNECTION QUANTITY | 9 SINGLE POWER OUTPUT |
OUTPUT CONNECTION TYPE | THREADED STUD AND TERMINAL STRIP SINGLE POWER OUTPUT |
OUTPUT CURRENT RATING | 75.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
OUTPUT CURRENT RATING | 8.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
OUTPUT CURRENT RATING | 8.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
OVERALL HEIGHT | 3.900 INCHES NOMINAL |
OVERALL LENGTH | 15.130 INCHES NOMINAL |
OVERALL WIDTH | 5.000 INCHES NOMINAL |
OPERATING AMBIENT TEMP RANGE | -0.1 TO 70.0 CELSIUS |
POWER SUPPLY EFFICIENCY LINE | 65.0 |
VENTILATION DESIGN TYPE | SINGLE FAN |