ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
INPUT VOLTAGE RATING | 180.0 AC VOLTS MINIMUM AND 265.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
INPUT VOLTAGE RATING | 90.0 AC VOLTS MINIMUM AND 132.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
OUTPUT CONNECTION QUANTITY | 4 3RD POWER OUTPUT |
OUTPUT CONNECTION QUANTITY | 4 4TH POWER OUTPUT |
OUTPUT CONNECTION QUANTITY | 4 1ST POWER OUTPUT |
OUTPUT CONNECTION QUANTITY | 4 2ND POWER OUTPUT |
OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
OUTPUT CONNECTION TYPE | TERMINAL STRIP 4TH POWER OUTPUT |
OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
OUTPUT CONTROL QUANTITY | 1 4TH POWER OUTPUT |
OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 4TH POWER OUTPUT |
OUTPUT CURRENT RATING | 3.0 DC AMPERES MINIMUM AND 22.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
OUTPUT CURRENT RATING | 500.0 DC MILLIAMPERES MINIMUM AND 5.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
OUTPUT CURRENT RATING | 500.0 DC MILLIAMPERES MINIMUM AND 2.5 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
OUTPUT CURRENT RATING | 500.0 DC MILLIAMPERES MINIMUM AND 2.5 DC AMPERES MAXIMUM 4TH POWER OUTPUT |
OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
OUTPUT VOLTAGE RATING | 24.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
OVERALL HEIGHT | 2.500 INCHES NOMINAL |
OVERALL LENGTH | 10.500 INCHES NOMINAL |
OVERALL WIDTH | 5.000 INCHES NOMINAL |
MAXIMUM OPERATING ALTITUDE RATING | 10000.0 FEET |
OPERATING AMBIENT TEMP RANGE | +0.1 TO 50.0 CELSIUS |