DUTY CYCLE | CONTINUOUS |
ENCLOSURE FEATURE | WATERTIGHT AND SUBMERSIBLE |
AC VOLTAGE RATING | 440.0 VOLTS NOMINAL |
ACTUATION METHOD | MAGNETIC |
ACTUATOR VOLTAGE | 440.0 AC |
AMBIENT TEMP | 50.0 CELSIUS |
CONTROL TYPE | LOCAL OR REMOTE |
FUSE ACCOMMODATION QUANTITY | 2 |
FUSE CURRENT RATING IN AMPS | 10.0 |
FEATURES PROVIDED | ACCESSORY LOCATION EXTERNAL AND CIRCUIT PROTECTION FUSE |
FREQUENCY IN HERTZ | 60.0 |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT AND SUBMERSIBLE |
HORSEPOWER RATING | 200.000 |
LOAD PROTECTION TYPE | UNDERVOLTAGE AND OVERLOAD |
OVERALL HEIGHT | 37.500 INCHES NOMINAL |
OVERALL LENGTH | 24.500 INCHES NOMINAL |
OVERALL WIDTH | 16.620 INCHES NOMINAL |
PART NAME ASSIGNED BY CONTROLLING AGENCY | CONTROLLER A.C. MAGNETIC SIZE 5 |
MOUNTING CONFIGURATION | SIX HOLES 0.656DIA FOR 0.625DIA MOUNTING BOLTS |
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
OPERATING VOLTAGE CHARACTERISTIC | FULL |
PHASE | THREE |
SIZE DESIGNATOR | 5 |
SPECIAL FEATURES | SUBMERSIBLE TO 15FEET;SHOCKPROOF GRADE A CLASS 1 OF MIL-S-901;FOUR REQUIRED PER VESSEL |
SWITCH FUNCTIONAL POSITIONS | START AND STOP AND RESET AND EMERGENCY RUN |