Description:
MOTOR,ALTERNATING CURRENT

Detail:
A MOTOR WHICH IS DESIGNED FOR OPERATION FROM AN ALTERNATING CURRENT SOURCE. SEE ALSO MOTOR, CONTROL.


Manufacturer Information:
4039701425LOUIS ALLIS CO THE THIS COMPANY HAS GONE BANKRUPT AND HAS BEEN PURCHASED BY 3 COMPANIES
MILM17060SERVICEA81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY CYCLEINTERMITTENT
ENCLOSURE FEATUREWATERTIGHT
CONNECTION TYPE AND VOLTAGE RATING IN VOLTS440.0 LINE TO NEUTRAL SINGLE INPUT
COOLING METHODFAN COOLED
CURRENT RATING METHODLOAD
CURRENT RATING IN AMPS11.000 SINGLE INPUT
FEATURES PROVIDEDVERTICAL MOUNTING POSITION
FREQUENCY IN HERTZ60.0 INPUT
FULL TOOTH LENGTH2.1250 INCHES NOMINAL SINGLE END
INCLOSURE SPECIFICATIONMIL-STD-108
LENGTH OF SHAFT FROM HOUSING0.000 INCHES SINGLE END
OVERALL HEIGHT11.875 INCHES
OVERALL LENGTH22.250 INCHES
OVERALL WIDTH11.875 INCHES
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
MOUNTING FACILITY CIRCLE DIAMETER10.000 INCHES
MOUNTING METHODFLANGE
PHASETHREE INPUT
POWER RATING7.5000 HORSEPOWER OUTPUT
ROTOR SPEED RATING IN RPM1800.0 SINGLE NO LOAD AND 1730.0 SINGLE FULL LOAD
SHAFT END CHARACTERISTICA17 FIRST STYLE AND A12 SECOND STYLE SINGLE END
SHAFT ROTATION DIRECTIONCLOCKWISE OR COUNTERCLOCKWISE SINGLE END
WINDING TYPEINDUCTION-SQUIRREL CAGE
STEP DIAMETER1.0000 INCHES NOMINAL SINGLE END
STEP LENGTH1.2500 INCHES NOMINAL SINGLE END
TEMP RATING40.0 OPERATING CELSIUS
TEST DATA DOCUMENT81349-MIL-17060A SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME INTERVAL30.0 MINUTES MAXIMUM ON AND 30.0 MINUTES MINIMUM OFF