National Stock Number: 5995-00-160-0930
Federal Supply Class: 5995
National Item Identification Number: 001600930
Description: CORD ASSEMBLY,ELECTRICAL
Detail: A definite length of CORD, ELECTRICAL having one or both ends processed and/or terminated in fittings which provide for connection to another item. It is generally used with telephone and communication equipment, such as headsets, category cable and switchboard patch cable. See also CABLE ASSEMBLY, (as modified and LEAD (as modified.)
|
Manufacturer Information:
3P15A | 06KW9 | LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP | 3P15A | 3B4M0 | LUCENT TECHNOLOGIES INC CORPORATE HEADQUARTERS | 3P15A | 64959 | AMERICAN TELEPHONE AND TELEGRAPH CO | A40460 | 72217 | TELEPHONE COMPANY OF AMERICA INCORPORATED | B40473 | 72217 | TELEPHONE COMPANY OF AMERICA INCORPORATED | P3K | 3B4M0 | LUCENT TECHNOLOGIES INC CORPORATE HEADQUARTERS | P3K | 64959 | AMERICAN TELEPHONE AND TELEGRAPH CO | P3K | 70408 | AT AND T CORP |
|
Techincal Specification:
CONDUCTOR ARRANGEMENT AND QUANTITY | 3 SINGLES | CONDUCTOR FORM | TINSEL ALL CONDUCTORS | CONDUCTOR QUANTITY | 3 | CROSS-SECTIONAL SHAPE STYLE | ROUND | OVERALL LENGTH | 6.000 FEET | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS | MATERIAL | RUBBER 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS | MATERIAL | PLASTIC POLYHEXAMETHYLENE ADIPAMIDE 1ST POSITION JACKET CORD | SPECIAL FEATURES | OUTER INSULATION SLATE COLORED | STYLE DESIGNATOR | INTERNAL AND EXTERNAL CONNECTOR | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 64959 BOTH ENDS ALL CONDUCTORS | TERMINATION TYPE | PLUG TELEPHONE BOTH ENDS ALL CONDUCTORS |
|
|