5925-01-533-4695 CIRCUIT BREAKER Index 1560-01-533-4697 ARMOR,SUPPLEMENTAL,SMALL ARMS-FR

National Stock Number:
5985-01-533-4696

Federal Supply Class:
5985

National Item Identification Number:
015334696

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
A327343880063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
A3273438-166948L3HARRIS TECHNOLOGIES, INC.
A3273438-180063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BEND ANGLE IN DEG45.0 SINGLE BEND E-PLANE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY8 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES
FLANGE INSIDE HEIGHT0.622 INCHES NOMINAL ALL FLANGES
FLANGE CONNECTING HOLE DIAMETER0.438 INCHES NOMINAL ALL FLANGES ALL CONNECTION FACILITIES
FLANGE DEPTH0.500 INCHES NOMINAL ALL FLANGES
FLANGE INSIDE WIDTH1.372 INCHES NOMINAL ALL FLANGES
FLANGE OUTSIDE HEIGHT1.940 INCHES NOMINAL ALL FLANGES
FLANGE OUTSIDE WIDTH2.690 INCHES NOMINAL ALL FLANGES
FLANGE QUANTITY2
FLANGE STYLECONTACT TYPE ALL FLANGES
FLEXIBILITYRIGID ALL TUBING SEGMENT
MATERIALCOPPER ALLOY 220 ALL TUBING SEGMENT
MAXIMUM OPERATING PRESSURE5.0 POUNDS PER SQUARE INCH GAGE
SPECIFICATION/STANDARD DATA81349 - MIL-W-85/1 GOVERNMENT SPECIFICATION AND 81349 - MIL-F-3922/52 GOVERNMENT SPECIFICATION
SPECIFIED FREQUENCY7.2 GIGAHERTZ MINIMUM AND 7.7 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO1.05
WAVEGUIDE OUTSIDE HEIGHT0.750 INCHES NOMINAL
WAVEGUIDE INSIDE HEIGHT0.622 INCHES NOMINAL
WAVEGUIDE INSIDE WIDTH1.372 INCHES NOMINAL
WAVEGUIDE OUTSIDE WIDTH1.500 INCHES NOMINAL
STYLE DESIGNATORBEND TYPE
SUPPLEMENTARY FEATURESFIRST TUBING SEGMENT LENGTH: 1.219 INCHES. SECOND TUBING SEGMENT LENGTH: 7.238 INCHES.
SURFACE TREATMENTPRIMER AND PAINT ALL TUBING SEGMENT OUTSIDE SURFACES
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT


Click here to Register for Free 30-day Trial