CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
FLANGE DEPTH | 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE DIAMETER | 0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.313 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.624 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.297 INCHES MINIMUM AND 1.327 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE WIDTH | 1.297 INCHES MINIMUM AND 1.327 INCHES MAXIMUM FIRST FLANGE |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
MATERIAL | ALUMINUM ALL TUBING SEGMENT AND FLANGE |
NOMINAL THREAD SIZE | 0.138 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
WAVEGUIDE INSIDE HEIGHT | 0.308 INCHES MINIMUM AND 0.313 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.619 INCHES MINIMUM AND 0.624 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
THREAD CLASS | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
THREAD SERIES DESIGNATOR | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
THREAD QUANTITY PER INCH | 32 FIRST FLANGE ALL CONNECTION FACILITIES |