5985-01-200-9510 WAVEGUIDE ASSEMBLY Index 5985-01-200-9512 WAVEGUIDE ASSEMBLY

National Stock Number:
5985-01-200-9511

Federal Supply Class:
5985

National Item Identification Number:
012009511

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
1303833900341LEXAN INDUSTRIES, INC
1303833905716RAYTHEON COMPANY
1303833918876U S ARMY AVIATION AND MISSILE COMMAND
130383391BS93ELECTRO DESIGN MANUFACTURING INC.
22582554647MICROTECH INC
79902154647MICROTECH INC
D10606166544FRONTGRADE TECHNOLOGIES INC.
TR5G4518306351MICROWAVE ENGINEERING CORPORATION
TRS64518306351MICROWAVE ENGINEERING CORPORATION


Techincal Specification:
CRITICALITY CODE JUSTIFICATIONFEAT
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE INSIDE HEIGHT0.503 INCHES MINIMUM AND 0.506 INCHES MAXIMUM FIRST FLANGE
FLANGE DEPTH0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH1.003 INCHES MINIMUM AND 1.006 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE QUANTITY2
FLANGE STYLECOVER TYPE FIRST FLANGE
FLEXIBILITYFLEXIBLE FIRST TUBING SEGMENT
FLEXIBILITYRIGID SECOND TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
INSERTION LOSS IN DECIBELS0.10
MAXIMUM OPERATING PRESSURE15.0 POUNDS PER SQUARE INCH GAGE
SPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
VOLTAGE STANDING WAVE RATIO1.25
WAVEGUIDE OUTSIDE HEIGHT0.496 INCHES MINIMUM AND 0.404 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM
WAVEGUIDE FIFTH LEG LENGTH2.590 INCHES MINIMUM AND 2.710 INCHES MAXIMUM
WAVEGUIDE FIRST LEG LENGTH0.940 INCHES NOMINAL
WAVEGUIDE FOURTH LEG LENGTH4.410 INCHES MINIMUM AND 4.530 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM
WAVEGUIDE SECOND LEG LENGTH2.270 INCHES NOMINAL
WAVEGUIDE THIRD LEG LENGTH4.010 INCHES NOMINAL
STYLE DESIGNATORFOUR BEND TYPE
TUBING WALL CONSTRUCTION STYLECORRUGATED FIRST TUBING SEGMENT
TUBING WALL CONSTRUCTION STYLESEAMLESS SECOND TUBING SEGMENT