5910-01-167-3424 RETAINER,CAPACITOR Index 5985-01-167-3426 WAVEGUIDE ASSEMBLY

National Stock Number:
5985-01-167-3425

Federal Supply Class:
5985

National Item Identification Number:
011673425

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
848001-13B150RAYTHEON COMPANY
848001-149956RAYTHEON COMPANY
848001-154X10RAYTHEON COMPANY
F12106351MICROWAVE ENGINEERING CORPORATION


Techincal Specification:
FLANGE STYLECONTACT, FOR DOUBLE RIDGE WAVEGUIDE ALL FLANGES
FLANGE QUANTITY2
BEND ANGLE IN DEG90.0 SINGLE BEND E-PLANE
WAVEGUIDE LONGER OFFSET DISTANCE6.000 INCHES NOMINAL
FLANGE INSIDE WIDTH0.968 INCHES NOMINAL ALL FLANGES
STYLE DESIGNATORBEND TYPE
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES
WAVEGUIDE OUTSIDE HEIGHT0.439 INCHES MAXIMUM
MATERIALALUMINUM ALLOY 6061 ALL FLANGE
MATERIALALUMINUM ALLOY 6063 SINGLE TUBING SEGMENT
FLANGE INSIDE HEIGHT0.323 INCHES NOMINAL ALL FLANGES
WAVEGUIDE OFFSET DISTANCE6.000 INCHES NOMINAL
WAVEGUIDE INSIDE HEIGHT0.320 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
INSERTION LOSS IN DECIBELS0.15
FLANGE OUTSIDE HEIGHT1.500 INCHES NOMINAL ALL FLANGES
WAVEGUIDE OUTSIDE WIDTH1.086 INCHES MAXIMUM
SURFACE TREATMENTPAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
SURFACE TREATMENTCHROMATE ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES
FLANGE CONNECTING HOLE DIAMETER0.144 INCHES MINIMUM ALL FLANGES ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES
MAXIMUM OPERATING PRESSURE25.0 POUNDS PER SQUARE INCH GAGE
FLANGE OUTSIDE WIDTH1.620 INCHES NOMINAL ALL FLANGES
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT
WAVEGUIDE INSIDE WIDTH0.965 INCHES NOMINAL
FLEXIBILITYRIGID SINGLE TUBING SEGMENT
VOLTAGE STANDING WAVE RATIO1.07
FLANGE DEPTH0.245 INCHES NOMINAL ALL FLANGES


Click here to Register for Free 30-day Trial