CRITICALITY CODE JUSTIFICATION | FEAT |
CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE DEPTH | 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM ALL FLANGES |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.166 INCHES NOMINAL ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE INSIDE DIAMETER | 0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.313 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.624 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE HEIGHT | 1.297 INCHES MINIMUM AND 1.327 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE WIDTH | 1.297 INCHES MINIMUM AND 1.327 INCHES MAXIMUM ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE ALL FLANGES |
FLEXIBILITY | RIGID ALL TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
MATERIAL | METAL ALL TUBING SEGMENT AND FLANGE |
MAXIMUM OPERATING PRESSURE | 10.0 POUNDS PER SQUARE INCH GAGE |
SPECIAL FEATURES | INCLUDES MTG PLATE AND BRACKET |
VOLTAGE STANDING WAVE RATIO | 1.10 |
WAVEGUIDE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.314 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |