Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
1518438-00102769LOCKHEED MARTIN CORPORATION
1518438-00156232LOCKHEED MARTIN CORPORATION
515380753711NAVAL SEA SYSTEMS COMMAND
51538075Z167ASTRO MICROWAVE INC
5153807-153711NAVAL SEA SYSTEMS COMMAND
PL 1518438-00102769LOCKHEED MARTIN CORPORATION
PL 1518438-00156232LOCKHEED MARTIN CORPORATION
PL 515380753711NAVAL SEA SYSTEMS COMMAND


Techincal Specification:
CRITICALITY CODE JUSTIFICATIONFEAT
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY8 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM AND 0.171 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES
FLANGE DEPTH0.480 INCHES MINIMUM AND 0.520 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT1.730 INCHES MINIMUM AND 1.770 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH2.480 INCHES MINIMUM AND 2.520 INCHES MAXIMUM ALL FLANGES
FLANGE QUANTITY2
FLANGE STYLECONTACT TYPE ALL FLANGES
FLEXIBILITYRIGID ALL TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
MATERIALALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE
MAXIMUM OPERATING PRESSURE15.0 POUNDS PER SQUARE INCH GAGE
SPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT
WAVEGUIDE OUTSIDE HEIGHT0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM
SURFACE TREATMENTCHROMATE AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES