5985-01-057-9587 WAVEGUIDE ASSEMBLY Index 5985-01-057-9589 WAVEGUIDE ASSEMBLY

National Stock Number:
5985-01-057-9588

Federal Supply Class:
5985

National Item Identification Number:
010579588

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
12592066544FRONTGRADE TECHNOLOGIES INC.
12592080006LITTON SYSTEMS INC AIRTRON DIV
584R193H0200443WAVELINE INC
584R193H0266544FRONTGRADE TECHNOLOGIES INC.
584R193H0280006LITTON SYSTEMS INC AIRTRON DIV
584R193H0297942NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
INSERTION LOSS IN DECIBELS0.020
MATERIALBERYLLIUM FIRST TUBING SEGMENT
PART NAME ASSIGNED BY CONTROLLING AGENCYWAVEGUIDE ASSEMBLY
PRECIOUS MATERIAL AND LOCATIONINTERNAL SURFACE PLATING SILVER
SPECIAL FEATURESINSERTION LOSS: .02 DECIBELS
SPECIAL TEST FEATURESTHE WAVEGUIDE CHANNEL SHALL BE CAPABLE OF BEING EVACUATED TO 29.5" OF MERCURY PRIOR TO FILLING WITH DRY AIR, NITROGEN OR SULFER HEXAFLUORIDE; THE EXTERNAL PRESSURE SHALL BE 15.4 PSIA TO 2.72 PSIA WITH AN INTERNAL PRESSURE OF 20 PSIG
SPECIFICATION/STANDARD DATA80204-ANSI Y14.5M, 1982 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD AND 96906-MIL-STD-100 GOVERNMENT STANDARD
SUPPLEMENTARY FEATURESPROOF PRESSURE: 30 PSIG; BURST PRESSURE: 50 PSIG; OPERATING TEMPEARTURE -54 DEGREES CELSIUS TO + 149 DEGREES CELSIUS; RADIO FREQUENCY LEAGAGE: ANY LEAKAGE FROM THE PART SHALL BE AT LEAST -80 DB BELOW THE LEVEL OF THE RF SIGNAL APPLIED TO THE INPUT PORTS; SUSCEPTIBILITY: THE PART SHALL HAVE AT LEAST 65DB OF ISOLATION BETWEEN THE EXTERNAL RF FIELDS AND INTERNAL SIGNAL PATHS; HUMIDITY TEST SHALL BE PERFORMED I/A/W MIL-STD-202, METHOD 106, EXCEPT OMIT STEP 7; VIBRATION TEST SHALL BE PERFORMED I/AW MIL-STD-202, METHOD 214 EXCEPT INPUT LEVERLS SHALL BE I/A/W FIGURE 4, CURVE A (5 HRS PER AXIS); SHOCK TEST I/A/W MIL-STD-810