ACTUATOR CURRENT TYPE AND RATING IN AMPS | 4.0 DC NOMINAL |
ACTUATOR OPERATING METHOD | RELAY |
ACTUATOR VOLTAGE IN VOLTS | 21.0 MINIMUM AND 29.0 MAXIMUM |
COUPLING POSITION QUANTITY | 3 |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE |
OVERALL HEIGHT | 1.645 INCHES MINIMUM AND 1.933 INCHES MAXIMUM |
OVERALL LENGTH | 4.500 INCHES MINIMUM AND 5.500 INCHES MAXIMUM |
OVERALL WIDTH | 2.220 INCHES MINIMUM AND 2.580 INCHES MAXIMUM |
MINIMUM CROSSTALK RATING IN DECIBELS | 80.0 SINGLE |
NOMINAL THREAD SIZE | 0.164 INCHES FLANGE CONNECTION FACILITY HOLE |
NOMINAL THREAD SIZE | 0.190 INCHES MOUNTING FACILITY HOLE |
POLE QUANTITY | 1 |
RF POWER HANDLING CAPABILITY | 400.0 KILOWATTS PEAK 2ND |
RF POWER HANDLING CAPABILITY | 400.0 WATTS AVERAGE 1ST |
WAVEGUIDE FLANGE TYPE | CHOKE |
SPECIFICATION/STANDARD DATA | 81439-MIL-DTL-55041/10 GOVERNMENT SPECIFICATION |
SWITCH RETURN MECHANISM TYPE | LATCHING |
SWITCH TYPE | NONTRANSFER |
SWITCHING TIME | 2.0 SECONDS |
TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE AND 3 RECTANGULAR FLANGE |
TEST DATA DOCUMENT | 81349-MIL-DTL-55041/10 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
THREAD SERIES DESIGNATOR | UNC FLANGE CONNECTION FACILITY HOLE |
THREAD SERIES DESIGNATOR | UNF MOUNTING FACILITY HOLE |
THROW QUANTITY | 2 |