CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE DEPTH | 0.360 INCHES MINIMUM AND 0.400 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE DIAMETER | 0.860 INCHES MINIMUM AND 0.900 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE HEIGHT | 0.253 INCHES MINIMUM AND 0.257 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE WIDTH | 0.508 INCHES MINIMUM AND 0.512 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE HEIGHT | 1.300 INCHES MINIMUM AND 1.340 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE WIDTH | 1.300 INCHES MINIMUM AND 1.340 INCHES MAXIMUM ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE ALL FLANGES |
FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
INSERTION LOSS IN DECIBELS | 0.50 |
MATERIAL | ALUMINUM ALLOY ALL FLANGE |
MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT |
MATERIAL | RUBBER NATURAL SINGLE TUBING JACKET |
MAXIMUM OPERATING PRESSURE | 30.0 POUNDS PER SQUARE INCH GAGE |
NOMINAL THREAD SIZE | 0.138 INCHES ALL FLANGES ALL CONNECTION FACILITIES |
PRECIOUS MATERIAL AND LOCATION | INTERNAL SURFACES SILVER |
PRECIOUS MATERIAL | SILVER |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
VOLTAGE STANDING WAVE RATIO | 1.15 |
WAVEGUIDE OUTSIDE HEIGHT | 0.335 INCHES NOMINAL |
WAVEGUIDE FIRST LEG LENGTH | 1.000 INCHES NOMINAL |
WAVEGUIDE FOURTH LEG LENGTH | 4.500 INCHES NOMINAL |
WAVEGUIDE INSIDE HEIGHT | 0.255 INCHES NOMINAL |
WAVEGUIDE INSIDE WIDTH | 0.510 INCHES NOMINAL |
WAVEGUIDE OUTSIDE WIDTH | 0.590 INCHES NOMINAL |
WAVEGUIDE THIRD LEG LENGTH | 2.880 INCHES NOMINAL |
STYLE DESIGNATOR | THREE BEND TYPE |
SURFACE TREATMENT | SILVER SINGLE TUBING SEGMENT INSIDE SURFACES |
THREAD CLASS | 2B ALL FLANGES ALL CONNECTION FACILITIES |
THREAD DIRECTION | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES |
THREAD SERIES DESIGNATOR | UNC ALL FLANGES ALL CONNECTION FACILITIES |