4820-01-008-2001 VALVE,RELIEF,PRESSURE AND TEMPER Index 5995-01-008-2006 CABLE ASSEMBLY,SPECIAL PURPOSE,E

National Stock Number:
5985-01-008-2003

Federal Supply Class:
5985

National Item Identification Number:
010082003

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
17-1000126648MEASUREMENT CONTROL DEVICES INC
266481753711NAVAL SEA SYSTEMS COMMAND
H10-213606351MICROWAVE ENGINEERING CORPORATION


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE DEPTH0.250 INCHES NOMINAL SECOND FLANGE
FLANGE DEPTH0.625 INCHES NOMINAL FIRST FLANGE
FLANGE CONNECTING FACILITY AND QUANTITY14 THREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY
FLANGE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.875 INCHES NOMINAL FIRST FLANGE
FLANGE OUTSIDE HEIGHT3.000 INCHES NOMINAL SECOND FLANGE
FLANGE OUTSIDE WIDTH1.875 INCHES NOMINAL FIRST FLANGE
FLANGE OUTSIDE WIDTH3.750 INCHES NOMINAL SECOND FLANGE
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE FIRST FLANGE
FLANGE STYLECONTACT TYPE SECOND FLANGE
MAXIMUM OPERATING PRESSURE15.0 POUNDS PER SQUARE INCH GAGE
SPECIAL FEATURESBOTH FLANGES COVERED WITH A MOISTURE SEAL ONE FLANGE COVERED WITH DWG N0 1651740-10001,AND OTHER FLANGE COVERED WITH DWG NO 2666572-10001
VOLTAGE STANDING WAVE RATIO1.03
WAVEGUIDE INSIDE HEIGHT0.494 INCHES MINIMUM AND 0.500 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.119 INCHES MINIMUM AND 1.125 INCHES MAXIMUM
WAVEGUIDE LENGTH3.470 INCHES MINIMUM AND 3.480 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH1.373 INCHES MINIMUM AND 1.383 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.748 INCHES MINIMUM AND 0.758 INCHES MAXIMUM
STYLE DESIGNATORSTRAIGHT TYPE
SURFACE TREATMENTENAMEL ALL FLANGE OUTSIDE SURFACES


Click here to Register for Free 30-day Trial