5999-00-971-2024 DELAY LINE Index 5840-00-971-2026 GENERATOR ASSEMBLY

National Stock Number:
5985-00-971-2025

Federal Supply Class:
5985

National Item Identification Number:
009712025

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
10300421530SPENCER INDUSTRIES INC
10300424930L3HARRIS TECHNOLOGIES, INC
103004628743DBM CO INC WAVEGUIDE GROUP


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE INSIDE DIAMETER1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.628 INCHES MINIMUM AND 0.631 INCHES MAXIMUM SECOND FLANGE
FLANGE DEPTH0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM SECOND FLANGE
FLANGE DEPTH0.610 INCHES MINIMUM AND 0.640 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH1.253 INCHES MINIMUM AND 1.256 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE WIDTH1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE WIDTH1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM FIRST FLANGE
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE FIRST FLANGE
FLANGE STYLECOVER TYPE SECOND FLANGE
FLEXIBILITYRIGID ALL TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
MATERIALALUMINUM ALLOY 6061 ALL TUBING SEGMENT AND FLANGE
WAVEGUIDE CENTER TO CENTER DISTANCE14.709 INCHES MINIMUM AND 14.729 INCHES MAXIMUM
WAVEGUIDE HEIGHT1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.628 INCHES MINIMUM AND 0.631 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH1.253 INCHES MINIMUM AND 1.256 INCHES MAXIMUM
STYLE DESIGNATORDOUBLE BEND TYPE
SURFACE TREATMENTANODIZE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT