5905-00-811-7471 RESISTOR,VARIABLE,NONWIRE WOUND, Index 5935-00-811-7476 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5985-00-811-7472

Federal Supply Class:
5985

National Item Identification Number:
008117472

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
G128-189-0010D0D0BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
G128-189-00188818KEARFOTT CORPORATION
UTW6201393306U T I CORP PA UNIFORM TUBES DIV


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.144 INCHES MINIMUM AND 0.147 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES
FLANGE DEPTH0.298 INCHES MINIMUM AND 0.328 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.394 INCHES MINIMUM AND 0.396 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE WIDTH0.705 INCHES MINIMUM AND 0.707 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT1.298 INCHES MINIMUM AND 1.328 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH1.298 INCHES MINIMUM AND 1.328 INCHES MAXIMUM ALL FLANGES
FLANGE QUANTITY2
FLANGE STYLECOVER TYPE ALL FLANGES
FLEXIBILITYRIGID SINGLE TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
INSERTION LOSS IN DECIBELS2.50
MATERIALALUMINUM ALLOY SINGLE TUBING SEGMENT
MATERIALCOPPER ALLOY ALL FLANGE
SPECIAL FEATURESINCLUDES THREE STRAPS EACH W/HOLE 10-32 UNF-2B
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT
VOLTAGE STANDING WAVE RATIO1.15
WAVEGUIDE OUTSIDE HEIGHT0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.309 INCHES MINIMUM AND 0.314 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.620 INCHES MINIMUM AND 0.625 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM
SURFACE TREATMENTENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES


Click here to Register for Free 30-day Trial