CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
FLANGE CONNECTING HOLE DIAMETER | 0.096 INCHES NOMINAL FIRST FLANGE SECOND CONNECTION FACILITY |
FLANGE CONNECTING HOLE DIAMETER | 0.140 INCHES MINIMUM AND 0.154 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.143 INCHES MINIMUM AND 0.149 INCHES MAXIMUM FIRST FLANGE FIRST CONNECTION FACILITY |
FLANGE INSIDE HEIGHT | 0.319 INCHES MINIMUM AND 0.323 INCHES MAXIMUM FIRST FLANGE |
FLANGE DEPTH | 0.235 INCHES MINIMUM AND 0.255 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE WIDTH | 0.689 INCHES MINIMUM AND 0.693 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.358 INCHES MINIMUM AND 1.390 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE WIDTH | 1.358 INCHES MINIMUM AND 1.390 INCHES MAXIMUM FIRST FLANGE |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE FIRST FLANGE |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATERIAL | ALUMINUM ALLOY ALL FLANGE |
SPECIAL FEATURES | 1ST FLANGE INCLUDES RF/PRESSURE SEAL W/0.625 IN. LG SCREW AND LOCKWASHER FOR EA MTG HOLE; 2ND FLANGE NOT PRESSURIZED |
VOLTAGE STANDING WAVE RATIO | 1.35 |
WAVEGUIDE INSIDE HEIGHT | 0.321 INCHES NOMINAL |
WAVEGUIDE INSIDE WIDTH | 0.691 INCHES NOMINAL |
WAVEGUIDE OUTSIDE HEIGHT | 0.421 INCHES NOMINAL |
WAVEGUIDE OUTSIDE WIDTH | 0.791 INCHES NOMINAL |
STYLE DESIGNATOR | THREE BEND TYPE |
SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |