CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM AND 0.506 INCHES MAXIMUM FIRST FLANGE |
FLANGE DEPTH | 0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM AND 1.006 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE |
FLANGE QUANTITY | 3 |
FLANGE STYLE | COVER TYPE FIRST FLANGE |
FLEXIBILITY | FLEXIBLE SECOND TUBING SEGMENT |
FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
MATERIAL | ALUMINUM ALLOY FIRST FLANGE |
MATERIAL | COPPER ALLOY FIRST TUBING SEGMENT |
PRECIOUS MATERIAL AND LOCATION | INTERNAL SURFACES SILVER |
PRECIOUS MATERIAL | SILVER |
WAVEGUIDE OUTSIDE HEIGHT | 0.500 INCHES NOMINAL |
WAVEGUIDE OUTSIDE WIDTH | 1.000 INCHES NOMINAL |
WAVEGUIDE INSIDE HEIGHT | 0.400 INCHES NOMINAL |
WAVEGUIDE INSIDE WIDTH | 0.900 INCHES NOMINAL |
SURFACE TREATMENT | SILVER FIRST TUBING SEGMENT OUTSIDE SURFACES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |