CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE INSIDE DIAMETER | 0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.313 INCHES MAXIMUM ALL FLANGES |
FLANGE DEPTH | 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.624 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE HEIGHT | 1.297 INCHES MINIMUM AND 1.327 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE WIDTH | 1.297 INCHES MINIMUM AND 1.327 INCHES MAXIMUM ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE ALL FLANGES |
FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT |
MAXIMUM OPERATING PRESSURE | 60.0 POUNDS PER SQUARE INCH GAGE |
NOMINAL THREAD SIZE | 0.138 INCHES ALL FLANGES ALL CONNECTION FACILITIES |
VOLTAGE STANDING WAVE RATIO | 1.30 |
WAVEGUIDE INSIDE HEIGHT | 0.3085 INCHES MINIMUM AND 0.3135 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.6195 INCHES MINIMUM AND 0.6245 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
STYLE DESIGNATOR | FOUR BEND TYPE |
THREAD CLASS | 2B ALL FLANGES ALL CONNECTION FACILITIES |
THREAD QUANTITY PER INCH | 32 ALL FLANGES ALL CONNECTION FACILITIES |
TUBING TWIST TYPE | TWISTABLE SINGLE TUBING SEGMENT |
TUBING WALL CONSTRUCTION STYLE | CONVOLUTE SINGLE TUBING SEGMENT |