CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY |
FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES NOMINAL ALL FLANGES SINGLE CONNECTION FACILITY |
FLANGE DEPTH | 0.4375 INCHES NOMINAL ALL FLANGES |
FLANGE INSIDE HEIGHT | 0.505 INCHES NOMINAL ALL FLANGES |
FLANGE INSIDE WIDTH | 1.0625 INCHES NOMINAL ALL FLANGES |
FLANGE OUTSIDE HEIGHT | 1.625 INCHES NOMINAL ALL FLANGES |
FLANGE OUTSIDE WIDTH | 1.625 INCHES NOMINAL ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | COVER TYPE ALL FLANGES |
FLEXIBILITY | RIGID ALL TUBING SEGMENT |
MATERIAL | ALUMINUM ALLOY ALL FLANGE |
MATERIAL | COPPER ALLOY ALL TUBING SEGMENT |
MAXIMUM OPERATING PRESSURE | 30.0 POUNDS PER SQUARE INCH GAGE |
PRECIOUS MATERIAL | SILVER |
PRECIOUS MATERIAL AND LOCATION | TUBING INSIDE SURFACE SILVER |
SPECIAL FEATURES | ONE 79.0 DEG BEND ANGLE |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |
VOLTAGE STANDING WAVE RATIO | 1.08 |
WAVEGUIDE OFFSET DISTANCE | 3.828 FEET NOMINAL |
WAVEGUIDE OUTSIDE HEIGHT | 0.500 INCHES NOMINAL |
WAVEGUIDE INSIDE HEIGHT | 0.400 INCHES NOMINAL |
WAVEGUIDE INSIDE WIDTH | 0.900 INCHES NOMINAL |
WAVEGUIDE OUTSIDE WIDTH | 1.000 INCHES NOMINAL |
STYLE DESIGNATOR | BEND TYPE |
SURFACE TREATMENT | SILVER ALL TUBING SEGMENT INSIDE SURFACES |