CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 8 THREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY |
FLANGE DEPTH | 0.480 INCHES MINIMUM AND 0.520 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE HEIGHT | 1.570 INCHES MINIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.610 INCHES MAXIMUM SECOND FLANGE |
FLANGE OUTSIDE WIDTH | 2.070 INCHES MINIMUM AND 2.110 INCHES MAXIMUM ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CONTACT TYPE ALL FLANGES |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
INSERTION LOSS IN DECIBELS | 0.04 |
MATERIAL | ALUMINUM SINGLE TUBING SEGMENT |
MATERIAL | RUBBER SYNTHETIC SINGLE TUBING JACKET |
MAXIMUM OPERATING PRESSURE | 10.0 POUNDS PER SQUARE INCH GAGE |
NOMINAL THREAD SIZE | 0.164 INCHES ALL FLANGES SINGLE CONNECTION FACILITY |
PRECIOUS MATERIAL AND LOCATION | FLANGE SURFACE SILVER |
PRECIOUS MATERIAL | SILVER |
TUBING WALL CONSTRUCTION STYLE | STRAIGHT SEAM SINGLE TUBING SEGMENT |
VOLTAGE STANDING WAVE RATIO | 1.10 |
WAVEGUIDE LENGTH | 4.062 INCHES NOMINAL |
WAVEGUIDE OUTSIDE HEIGHT | 0.497 INCHES MINIMUM AND 0.503 INCHES MAXIMUM |
WAVEGUIDE CENTER TO CENTER DISTANCE | 1.250 INCHES NOMINAL |
WAVEGUIDE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.997 INCHES MINIMUM AND 1.003 INCHES MAXIMUM |
STYLE DESIGNATOR | OFFSET BEND TYPE |
SURFACE TREATMENT | CADMIUM ALL FLANGE OUTSIDE SURFACES |
SURFACE TREATMENT | CADMIUM SINGLE TUBING SEGMENT OUTSIDE SURFACES |
SURFACE TREATMENT | ALUMINUM SINGLE TUBING SEGMENT INSIDE SURFACES |
THREAD CLASS | 2B ALL FLANGES SINGLE CONNECTION FACILITY |
THREAD DIRECTION | RIGHT-HAND ALL FLANGES FIRST CONNECTION FACILITY |
THREAD SERIES DESIGNATOR | UNC ALL FLANGES SINGLE CONNECTION FACILITY |