5970-01-352-5635 INSULATION SLEEVING,ELECTRICAL,S Index 2940-01-352-5637 FILTER ELEMENT,INTAKE AIR CLEANE

National Stock Number:
5970-01-352-5636

Federal Supply Class:
5970

National Item Identification Number:
013525636

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
13238529-218876U S ARMY AVIATION AND MISSILE COMMAND
562A032-406090TE CONNECTIVITY CORPORATION
B-562A03259659REMTEK CORP


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES1.420 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.770 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH1.940 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG45.0 NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG15.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.060 INCHES MAXIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
FOURTH BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
FOURTH BRANCH WALL THICKNESS0.060 INCHES MAXIMUM AS SUPPLIED
FOURTH BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.760 INCHES MINIMUM AS SUPPLIED
MAIN BODY INSIDE DIAMETER0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.070 INCHES MAXIMUM AS SUPPLIED
MAIN BODY WALL THICKNESS0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALPLASTIC CROSS-LINKED POLYOLEFIN
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.060 INCHES MAXIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-1 TO 4 CABLES
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.060 INCHES MAXIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY