5970-01-344-0720 INSULATION SLEEVING,ELECTRICAL,S Index 4720-01-344-0722 HOSE,AIR DUCT

National Stock Number:
5970-01-344-0721

Federal Supply Class:
5970

National Item Identification Number:
013440721

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
462A422-5006090TE CONNECTIVITY CORPORATION
TG202521-4128839TELEDYNE INDUSTRIES INC TELEDYNE POWER SYSTEMS DIV


Techincal Specification:
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES2.670 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH2.670 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
ENVIRONMENTAL PROTECTIONFLAME RESISTANT AND MILDEW RESISTANT
FIRST BRANCH INSIDE DIAMETER0.450 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.810 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY OVERALL LENGTH5.340 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.450 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.350 INCHES MINIMUM AS SUPPLIED
MAIN BODY WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALRUBBER,SYNTHETIC,VITON POLYMER BLEND,RT-1313,RAYCHEM CORP
PROPRIETARY CHARACTERISTICSPACS
MINIMUM TENSILE STRENGTH2200 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.450 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.810 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
TEMP RATING-70.0 DEG CELSIUS
THIRD BRANCH INSIDE DIAMETER0.450 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.810 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY