7690-01-217-1513 MARKER,IDENTIFICATION Index 5970-01-217-1515 INSULATION SLEEVING,ELECTRICAL,S

National Stock Number:
5970-01-217-1514

Federal Supply Class:
5970

National Item Identification Number:
012171514

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
502A812-3/4206090TE CONNECTIVITY CORPORATION
GS830EV502A26512NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.110 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.280 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
FOURTH BRANCH INSIDE DIAMETER0.110 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH INSIDE DIAMETER0.280 INCHES MINIMUM AS SUPPLIED
FOURTH BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.470 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.900 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH2.750 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE
MATERIALPLASTIC POLYOLEFIN
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.110 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.280 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SPECIAL FEATURESINSIDE COATED WITH S-1017 ADHESIVE
TEMP RATING-55.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.110 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.280 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY