5970-01-205-8263 INSULATION SLEEVING,ELECTRICAL Index 4720-01-205-8265 HOSE,AIRDUCT

National Stock Number:
5970-01-205-8264

Federal Supply Class:
5970

National Item Identification Number:
012058264

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
462A046-3-06/4206090TE CONNECTIVITY CORPORATION


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER1.030 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
MAIN BODY INSIDE DIAMETER1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER2.190 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE
MATERIALPLASTIC POLYOLEFIN
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER1.030 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SPECIAL FEATURESINSIDE ADHESIVE COATED
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
THIRD BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER1.030 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY