4820-01-204-0594 VALVE,REGULATING,TEMPERATURE Index 5970-01-204-0596 INSULATION SLEEVING,ELECTRICAL,S

National Stock Number:
5970-01-204-0595

Federal Supply Class:
5970

National Item Identification Number:
012040595

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
462A023-3/4206090TE CONNECTIVITY CORPORATION
GS830R2-3A26512NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.980 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES1.690 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.460 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
MAIN BODY INSIDE DIAMETER0.052 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.000 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH3.670 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE
MATERIALPLASTIC POLYOLEFIN
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
SECOND BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.460 INCHES MINIMUM AS SUPPLIED
SPECIAL FEATURESINSIDE COATED WITH RAYCHEM S-1017 ADHESIVE
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.460 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY