5985-01-199-9100 ATTENUATOR,VARIABLE Index 5970-01-199-9102 INSULATION SLEEVING,ELECTRICAL,S

National Stock Number:
5970-01-199-9101

Federal Supply Class:
5970

National Item Identification Number:
011999101

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
1183115719200US ARMY ARDEC RDECOM
1310-1-GK0720HELLERMANNTYTON LTD
1310-1-GK1793HELLERMANNTYTON LIMITED
462A214-2506090TE CONNECTIVITY CORPORATION
462A214-25K1010TYCO ELECTRONICS UK LTD
A10191K0967MBDA UK LTD


Techincal Specification:
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH2.000 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES1.750 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT
FIRST BRANCH INSIDE DIAMETER0.250 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.500 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
MAIN BODY OVERALL LENGTH3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.600 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.200 INCHES MINIMUM AS SUPPLIED
MATERIAL DOCUMENT AND CLASSIFICATIONRT-1325,RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE
MATERIALRUBBER
MINIMUM TENSILE STRENGTH2175 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.250 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.500 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUS


Click here to Register for Free 30-day Trial