5970-01-036-5979 INSULATION SLEEVING,ELECTRICAL,S Index 1660-01-036-5981 DUCT ASSEMBLY,AIR CONDITIONING-H

National Stock Number:
5970-01-036-5980

Federal Supply Class:
5970

National Item Identification Number:
010365980

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
342A112-1206090TE CONNECTIVITY CORPORATION
342A112-12-006090TE CONNECTIVITY CORPORATION


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES0.900 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH0.840 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG40.0 MINIMUM AND 50.0 MAXIMUM AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS200.0
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT
FIRST BRANCH INSIDE DIAMETER0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
HEAT SHRINKAGE RATING IN PERCENT50.0
MAIN BODY INSIDE DIAMETER0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH1.760 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-1312 MFR REF SINGLE MATERIAL RESPONSE
MATERIALRUBBER SYNTHETIC
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
STYLE DESIGNATORTRANSITION-45 DEGREES
TEMP RATING-55.0 CELSIUS AND 225.0 CELSIUS