5970-01-020-3417 INSULATION SLEEVING,ELECTRICAL,S Index 5970-01-020-3419 INSULATION SLEEVING,ELECTRICAL,S

National Stock Number:
5970-01-020-3418

Federal Supply Class:
5970

National Item Identification Number:
010203418

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
54204-100779TE CONNECTIVITY CORPORATION
603081-100779TE CONNECTIVITY CORPORATION
91344-20TEB9XL TECHNOLOGIES INC
F23-50FR06090TE CONNECTIVITY CORPORATION
F23-50FR50015SIGMAFORM CORP


Techincal Specification:
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS275.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND OIL RESISTANT AND OZONE RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.190 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.500 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
FOURTH BRANCH INSIDE DIAMETER0.190 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH INSIDE DIAMETER0.500 INCHES MINIMUM AS SUPPLIED
FOURTH BRANCH WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.725 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.250 INCHES MINIMUM AS SUPPLIED
MAIN BODY WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALPLASTIC POLYOLEFIN
MINIMUM TENSILE STRENGTH1000 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.190 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.500 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SPECIAL FEATURESSUPPLIED WITH SEALANT
TEMP RATING-65.0 CELSIUS AND 136.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.190 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.500 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY