7690-01-003-7639 MARKER,IDENTIFICATION Index 8410-01-003-7644 HOOD,WOMAN'S BERET

National Stock Number:
5970-01-003-7640

Federal Supply Class:
5970

National Item Identification Number:
010037640

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
13217E8002-197403CECOM LR CENTER
13217E8002B97403CECOM LR CENTER
401A212-306090TE CONNECTIVITY CORPORATION


Techincal Specification:
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.210 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.050 INCHES MAXIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
FOURTH BRANCH INSIDE DIAMETER0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH INSIDE DIAMETER0.210 INCHES MINIMUM AS SUPPLIED
FOURTH BRANCH WALL THICKNESS0.050 INCHES MAXIMUM AS SUPPLIED
FOURTH BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH2.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE
MATERIALPLASTIC POLYOLEFIN
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.210 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS0.050 INCHES MAXIMUM AS SUPPLIED
TEMP RATING-55.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.210 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.050 INCHES MAXIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY


Click here to Register for Free 30-day Trial