5970-00-998-2225 INSULATION SLEEVING,ELECTRICAL,S Index 5970-00-998-2229 INSULATION SLEEVING,ELECTRICAL,S

National Stock Number:
5970-00-998-2226

Federal Supply Class:
5970

National Item Identification Number:
009982226

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
381A015-5-0006090TE CONNECTIVITY CORPORATION
GS830N-226512NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES3.250 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH2.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG22.5 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS200.0
FIRST BRANCH INSIDE DIAMETER0.310 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.440 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.090 INCHES MAXIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY INSIDE DIAMETER0.310 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.680 INCHES MINIMUM AS SUPPLIED
MAIN BODY WALL THICKNESS0.090 INCHES MAXIMUM AS SUPPLIED
MAIN BODY WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALRUBBER CHLOROPRENE CLASS CR
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.310 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.440 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.090 INCHES MAXIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-Y
TEMP RATING-55.0 CELSIUS AND 150.0 CELSIUS