5840-00-992-3465 SHIELD ASSEMBLY Index 5970-00-992-3472 INSULATION SLEEVING,ELECTRICAL,S

National Stock Number:
5970-00-992-3470

Federal Supply Class:
5970

National Item Identification Number:
009923470

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
10041163-218876U S ARMY AVIATION AND MISSILE COMMAND
10556632-219200US ARMY ARDEC RDECOM
11336700-0227963GENERAL DYNAMICS INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
11336700-023CYA2GENERAL DYNAMICS MISSION SYSTEMS, INC.
18039F2181GDI SIMULATION
202-25212-280378TRIUMPH AEROSTRUCTURES, LLC
203-1-B7K0720HELLERMANNTYTON LTD
203-1-B7K1793HELLERMANNTYTON LIMITED
382A023-306090TE CONNECTIVITY CORPORATION
382A023-3-006090TE CONNECTIVITY CORPORATION
493H134-1209993M CO ADMININISTRATIVE ELECTRONIC & COMMUNICATIONS
493H134-1533873M COMPANY
6010ECCP06090TE CONNECTIVITY CORPORATION
62A5A142-230003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
908145-162228MEGGITT DEFENSE SYSTEMS, INC.
91455318F6481THALES SA
B10175K0967MBDA UK LTD
C507230557957US ARMY ELECTRONIC WARFARE LABORATORY SEE CAGE CODE 80063
C507230580063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
C5075979-1057958SIGNALS WARFARE PROJECT MANAGER
FV2044230/4U0795QINETIQ
GS830AE2-326512NORTHROP GRUMMAN SYSTEMS CORPORATION
LS9751-598897LOCKHEED MARTIN CORP
SS7073-180178286SIKORSKY AIRCRAFT CORPORATION


Techincal Specification:
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES1.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.700 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG22.5 NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
COLORBLACK
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
MAIN BODY INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
MAIN BODY WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALPLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MIL-I-81765/1,TYPE I
PROPRIETARY CHARACTERISTICSPACS
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-Y
TEMP RATING-55.0 DEG CELSIUS