5961-00-971-6375 TRANSISTOR Index 5970-00-971-6380 INSULATION SLEEVING,ELECTRICAL,S

National Stock Number:
5970-00-971-6377

Federal Supply Class:
5970

National Item Identification Number:
009716377

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
1155371518876U S ARMY AVIATION AND MISSILE COMMAND
213-1-B7K0720HELLERMANNTYTON LTD
213-1-B7K1793HELLERMANNTYTON LIMITED
381A015-306090TE CONNECTIVITY CORPORATION
492H126-1209993M CO ADMININISTRATIVE ELECTRONIC & COMMUNICATIONS
5970PL08426649009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
5970PL17319219009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
5970PL17738729009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
SS7073-170078286SIKORSKY AIRCRAFT CORPORATION


Techincal Specification:
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH2.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG22.5 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS200.0
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES3.250 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.310 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.440 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.090 INCHES MAXIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
MAIN BODY WALL THICKNESS0.090 INCHES MAXIMUM AS SUPPLIED
MAIN BODY WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.310 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.680 INCHES MINIMUM AS SUPPLIED
MATERIALPLASTIC POLYOLEFIN
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.310 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.440 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.090 INCHES MAXIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.090 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-Y
TEMP RATING-55.0 CELSIUS AND 225.0 CELSIUS